Product advantages:
Smart mobile water dispenser
Intelligent one-key disinfection management
Unique ion exchange system structure design
All-round system process data monitoring
Smart water intake and consumables management
Technical features:
1 LCD touch screen (4.3) control system has automatic fault detection indication, automatic diagnosis system, water quality exceeding alarm, the system has automatic alarm of consumable failure and reminding of replacement, built-in regular flushing program, built-in regular automatic cycle program, water shortage, power failure automatic Protection alarm, automatic alarm and shutdown when the system is short of water, and automatically in standby state when the water is full;
2. The machine is designed to take water regularly. Customers can set the required water volume at will according to their own water consumption needs and press the button to take water. When the corresponding water volume is reached, it will automatically shut down to avoid the phenomenon of water overflowing;
3. There is a one-key disinfection function of pure water and ultrapure water in the host, and the pressure can be relieved by one key when the water pressure is too high;
4 The unique membrane treatment technology and accessories in the United States can be adapted to different municipal tap water around;
5 Built-in ultra-pure water circulation program design, stable water quality, convenient and fast water intake and water use, no need to wait, real-time monitoring data.
6. The multi-function LCD touch screen system has unique password protection function and operation parameter storage function to ensure the safety of operation data;
7. Automatic continuous water production, real-time operating status display, adjustable operating parameters; water production system and circuit system are completely separated, completely eliminating potential safety hazards;
8 The equipment complies with (National Laboratory Water Standard GB/T6682-2008), Chinese National Standard for Electronic Grade Ultrapure Water (GB/T11446.1-1997), and American Reagent Grade Water (CAP, ASTM, NCCLS) standard;
9 The company has passed the EU CE certification and ISO9001-2008 international quality management system certification;
Optional:
※The one-piece water intake handle is comfortable to hold and can be operated with only one hand, which is easy to use; the water intake arm bracket can be raised and lowered freely, rotated 360°, with a non-slip base; it has an independent water intake function (ultra-pure water);
※Multifunctional water tank (30L): The water tank air filter reduces environmental pollutants, such as CO?, particulate matter, bacteria and volatile organic compounds; the dual liquid level sensor device of the water tank provides additional security for the system, and the independent high liquid level sensing control realizes Abnormal ultra-high liquid level (110%) protection, in coordination with the whole process liquid level sensing, to achieve normal high liquid level (100%) and low liquid level (10%) ultra-pure water protection.
Technical parameter:
product name |
FYY basic application type |
FFX Fundamental Analysis |
FBZ standard reagent type |
FCR heat removal type |
FDY low organic type |
FJY genotype research type |
||
Product water quality |
tertiary water |
secondary water |
first grade water |
first grade water |
first grade water |
first grade water |
||
Product Model |
FYY(5-20)01/02 |
FFX(5-20)01/02 |
FBZ(5-20)01/02 |
FCR(5-20)01/02 |
FDY(5-20)01/02 |
FJY(5-20)01/02 |
||
working conditions |
Inlet water: Municipal tap water Source water pressure: 0.15Mpa—0.5Mpa Inlet water temperature: 5-40℃ |
|||||||
Conductivity (μS/cm) |
≤5 |
≤0.5 |
≤0.067 |
≤0.055 |
≤0.055 |
≤0.055 |
||
Resistivity (MΩ.cm) |
≥0.2 |
≥2 |
≥15 |
≥18.25 |
≥18.25 |
≥18.25 |
||
TOC content (ppb) |
- |
- |
≤10 |
≤5 |
≤1-2 |
≤1-2 |
||
Endotoxin content (EU/ml) |
- |
- |
- |
≤0.001 |
- |
≤0.001 |
||
Particulate Matter (0.22μm) |
- |
- |
≤1/ml |
≤1/ml |
≤1/ml |
≤1/ml |
||
Bacteria (CFU/ml) |
- |
- |
≤0.01 |
≤0.01 |
≤0.01 |
≤0.01 |
||
Intake flow rate (L/min) |
1-2 |
1-2 |
1-2 |
1-2 |
1-2 |
1-2 |
||
Water production flow rate (L/h) |
5-20 |
5-20 |
5-20 |
5-20 |
5-20 |
5-20 |
||
Metal cation (ppb) |
- |
- |
Fe、Al、Cr、Ni、Cu<0.005ppb Zn、K<0.02ppb、Na<0.01ppb |
|||||
Anion (ppb) |
- |
- |
Cl-、SO42- <0.01ppb、NO2-、NO3-<0.02ppb |
|||||
Soluble silicon (SiO2)/(mg/L) |
- |
<0.02 |
<0.01 |
|||||
Absorbance (254nm.1cm optical path) |
- |
<0.01 |
<0.001 |
|||||
Dimensions (mm) |
430×500×560(LxWxH)mm |
|||||||
weight |
30kg |
|||||||
Model Analysis FBZ (5-20) 01/02-UP Standard Reagent Standard Series (5-20) means the water production is 5L, 10L, 15L, 20L/H (5-20) 01 refers to single-stage reverse osmosis, (5-20) 02 refers to double-stage reverse osmosis |
Application areas:
FYY (basic application): physical and chemical analysis experiments, hydrogen generators, test utensils washing, washing machines, drinking water for laboratory animals, high-purity steam generators, sterilizers and other instruments, before ultrapure water systems using distilled water as source water set unit;
·FFX (basic analysis): biochemical instrument, solution preparation, preparation of chemical reagents, buffer solution, culture medium, university student experiments, physical and chemical testing and other routine qualitative analysis experiments;
FBZ (standard reagent): used for buffer preparation, chemical analysis and inspection for atomic absorption (AA), atomic fluorescence (AFS), high performance liquid phase (HPLC), mass spectrometry (MC), plasma emission spectroscopy (ICP);
FCR (pyrogenic type): amino acid analysis, protein purification, electrophoresis/gel analysis, animal and plant cell culture, molecular biology experiments, electrophoresis, molecular biology experiments, PCR;
FDY (low organic matter): ion chromatography, trace metal analysis, preparation of high-purity standard solutions, quantitative analysis of trace elements, HPLC high performance liquid chromatography; toxicity detection, HPLC, TOC analysis, IC, GC/MS, ICP/MS analyze;
FJY (Gene Research): DNA/RNA preparative sequencing; HPLC (amino acid, penicillin analysis); protein purification/analysis; toxicity detection; TOC detection; IVF, PCR; cell and tissue culture, capillary electrophoresis, biological experiments;